Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe – HI6421P
HI6421P is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated module designed for fresh and saltwater measurements of dissolved oxygen.
HI6421P includes the HI764833 polarographic probe. Slim and versatile, this probe covers a wide range of dissolved oxygen and has a built-in thermistor temperature sensor that compensates for temperature variations. The slim design allows for convenient measurement in test tubes and Biological Oxygen Demand (BOD) bottles.
Durable and robust, the probe features a platinum cathode and Ag/AgCl anode assembly. Accurate and with a fast response time, readings are not flow dependent.
The probe is fitted with durable (PTFE), oxygen permeable, screw on membrane caps. Caps are filled with electrolyte and easily installed on the probe.
Concentration measurements are automatically compensated for barometric pressure, temperature, and salinity. Barometric pressure and temperature are automatically measured and compensated. Salinity is automatically compensated by setting manually the salinity concentration of the water being measured.
Additional features include built-in methods and calculations for the measurement of BOD (Biological Oxygen Demand), OUR (Oxygen Uptake Rate), and SOUR (Specific Oxygen Update Rate).
Pressure compensation is done automatically (built-in barometer) or users have the option to manually enter required value. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inHg, psi, atm.
Features at-a-glance
User interface
- 7-inch capacitive touch screen with multi-touch support
- Capacitive touch back, home and system menu keys
- User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions
The user can select between five different views:
- Basic measurement configuration
- Simple GLP with calibration information
- Full GLP with electrode status and calibration point details
- Live updated, interactive graph
- Tabulated data with date, time, and notes
Measurement
- Measure %Sat, mg/L, ppm (DO); mg/L, ppm (BOD); mg/L (OUR); ppm, mg/L (SOUR)
- Application-specific profiles allow quick and direct measurement without the need to update the
sensor and system settings - Active log during measurement Measurement stability indicator (using the Stability Criteria setting)
- Reading modes: direct and direct/auto-hold
- Temperature compensation can be Automatic or set manually
- Audible and/or alarm messages for measurements outside of predefined limits
- Galvanic isolation for measurement
Calibration
- One or two points calibration at 0% and/or 100% saturation
- Single point manual calibration in mg/L or % saturation using a reference method
- Non-volatile memory saves data and settings
Logging
- Data log collection of at least 1,000,000 data points (with time and date stamp)
- Logging types: manual, automatic, auto-hold
- Sample ID for manual and auto-hold data
Connectivity
- Transfer logged data ta USB thumb drive
- Log files that include measurements and calibration data (as .csv file)
- FTP and email for log export via Ethernet and Wi-Fi connection
- USB type A for USB stick, keyboard, and printer
- USB type C for USB stick and PC connection
Help section for meter guidance
- Video support presentation of main functionalities
Specification :
SKU | HI6421P-02 |
Product Name | Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe – HI6421P |
Quote Required | Yes |
DO (HI764833 Polarographic probe) Range | 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0 % saturation |
DO (HI764833 Polarographic probe) Resolution | 0.01 mg/L (ppm); 0.1 % saturation |
DO (HI764833 Polarographic probe) Accuracy | ±1.5 % of reading ±1, least significant digit |
Barometric Pressure Range | 450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; / 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm |
Barometric Pressure Resolution | 1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm |
Barometric Pressure Accuracy | ±3 mmHg within ±15 % from the calibration point / ±3 mmHg ±1 least significant digit |
Temperature Range | −20.0 to 120.0 °C / −4.0 to 248.0 °F / 253.0 to 393.0 K |
Temperature Resolution | 0.1 °C; 0.1 °F; 0.1 K |
Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
DO Calibration Points | Automatic-two points / User standard-single point |
DO Calibration Standards | 0 and 100% saturation |
DO Calibration Reminder | Disabled / Daily |
Temperature Compensation | Automatic or Manual |
Reading Modes | Direct Direct/Autohold |
Reading Stability criteria | Accurate Medium Fast |
Reading Isopotential | 7.000 or 4.010 |
Reading Sampling rate | 1000 ms |
DO Views Basic | Measurement (DO, Temperature) Stability status |
DO Views Simple GLP | Basic view information Last calibration date, offset, average slope |
DO Views Full GLP | Simple GLP information and calibration point details |
DO Views Table | Measurements updated every second are displayed in table |
DO Views Graph (Plot) | Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) |
Logging Type | Automatic, Manual, Autohold |
Logging Number of records | 50 000 maximum per file Stores at least 1 000 000 data points per user |
Logging Automatic interval | 1, 2, 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
Logging Sample ID | Incremental mode |
Logging Export option | .csv file format |
Users | Up to 9 users and the default administrator account |
Connectivity USB-A | 2 ports for keyboard input or USB thumb drive |
Connectivity USB-C | 1 port for PC connectivity and USB-C type thumb drive |
Connectivity Wi-Fi & Ethernet | FTP / Web server Log transfer and download Email |
Connectivity RS232 | Connecting peripherals |
Power supply | DC adapter 100-240AC to 24VDC 2.5A |
Environment | 0 – 50 °C / 32 – 122 °F / 273 – 323 K maximum 95% RH non-condensing |
Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
Weight | Approximately 1.2 kg (26.5 lbs.) |