pH/ORP/Temperature Benchtop meter with Calibration Check – HI3220
HI3220 is a professional pH/ORP/Temperature bench meter with a graphic LCD designed to provide high accuracy and ease of use both in the laboratory as well as in harsh industrial conditions.This instrument is a single input model measuring pH, ORP, and temperature utilizing a single channel.
This instruments is a single input model measuring pH, ORP, and temperature utilizing a single channel. A Relative mV feature is also available.
This meter features Hanna’s exclusive Calibration Check™, a diagnostics system that ensures accurate readings every time. Calibration Check system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated buffer solution by alerting users of potential problems during the calibration process.
Throughout the calibration process, users are guided step-by-step by the on-screen tutorial. After calibration, a probe condition indicator is displayed on the LCD informing the user of the overall electrode status.
Main Features:
- Single input channel
- Up to 5 point pH calibration with 7 standard buffers and 5 custom buffers to choose from
- Messages on the graphic LCD for an easy and accurate calibration
- Diagnostic features to alert the user when the electrode needs cleaning
-
- Three types of logging modes (for pH and mV)
- Stability logging
- Interval logging
- Log-on-demand
- Relative mV measurements
- Log on demand up to 200 samples
- Log interval with log on stability feature up to 600 records
- Auto Hold feature, to freeze first stable reading on the LCD
- GLP feature, to view last calibration data for pH or Rel mV
- PC Interface
Manual : Download
Specification :
SKU | HI3220 |
Product Name | pH/ORP/Temperature Bench Meter with Calibration Check – HI3220 |
Quote Required | Yes |
pH Range | -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH |
pH Resolution | 0.1 pH / 0.01 pH / 0.001 pH |
pH Accuracy | ±0.01 pH / ±0.002 pH |
pH Calibration | Up to 5 points / 7 standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) / 5 custom buffers |
ORP Range | ±2000.0 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±0.2 mV |
Temperature Range | -20.0 to 120.0 °C (-4.0 to 248.0 °F) |
Temperature Resolution | 0.1 °C (0.1 °F) |
Temperature Accuracy | ±0.2 °C (±0.4 °F) (excluding probe error) |
Rel mV offset range | ±2000 mV |
Slope calibration | From 80 to 110% |
Temperature compensation | Manual / Automatic |
Electrode | Hanna BNC connection pH / ORP electrodes |
Temperature probe | RCA Connection / Recommended option |
LOG on demand | 200 samples |
Lot logging | 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes / AutoEnd (maximum 600 samples) |
Environment | 0 to 50 °C (32 to 122 °F) / max. RH 55% non-condensing |
Power Supply | 12 Vdc power adapter |
PC interface | opto-isolated USB |
Dimensions | 235 x 207 x 110 mm (9.2 x 8.14 x 4.33 in.) |
Weight(meter only) | 1.8 Kg (4.1 lbs) |